Part Number Hot Search : 
8F400 LV5980MX MK1442 MA4M3150 FSQ0765 MB91F233 MRF160 CLE230
Product Description
Full Text Search
 

To Download A-TB72 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  zzzehoohohfwulfdofrpdx  3 lvwkhjoredoqdphri0dwvxvklwd(ohfwulf:runv A-TB72 fla t a a time s wit c he s a - tb72 72 q 72 2. 835 72 2.835 7 5 . 2 2. 961 90 3 . 5 4 3 m a n u r a l s wit ch power status indicator: q uart z power-failure compensation t y pe . frequenc y switchable: ac motor t y pes . power suppl y t e rmin a l s lo ad terminal s ? a u to a n d m a n ua l mo des a r ese l ec t ab l e f o r co ntr o l . quick mountable. din rail mountin g possibl e easy-to-read. directly read- able clock. ? present time is trimmable every 1 minute. on settin g s are colore d on the dial. ? operation settin g times are foun d at a g lance with red indicator . settin g elements inte g rated at 1 5 m i nute i ntervals throu g hout the cloc k c ir cu mf e r e n ce. space-savin g. de p th in the box is les s th a n 21.7mm .854inch . (includin g the panel thickness. ) ? load can be turned on and off ever y 15 minute s (maximum 48 on and off actions per da y ) , allowin g minute daily time control . p a r t name s flush mountin g typ e surface mountin g typ e mm in ch f ea t u r es 1. din72 s iz es m a rt tim es wit ch flush mountin g type is as thin as 32m m 1.2 60 inc h and de p th in the box is les s th a n 21.7mm . 85 4inc h . 2. eas y to read directl y readabl e c l oc k . 3 . load can be turned on and of f every 15 minutes with the 96 settin g e l e m e nt s. 4. quartz p ower-failure com p ensatio n t y pe commonl y usable over 100 t o 24 0 v a c. ty p e r ate d operat i n g vo l ta ge fl us h mount i n g typ e surface mountin g typ e ac motor t y p e quartz power-failure compensation t y p e 1 00 v a c 11 0 v a c 12 0 v a c 2 00 v a c 22 0 v a c 24 0 v a c 1 00 to 24 0 v a c A-TB72-d-hr1a-1 00v A-TB72-d-hr1a-110 v A-TB72-d-hr1a-12 0v A-TB72-d-hr1a-2 00v A-TB72-d-hr1a-220 v A-TB72-d-hr1a-24 0v A-TB72- q -hr1a-ac f A-TB72-dd-hr1 c -1 00v A-TB72-dd-hr1c-110 v A-TB72-dd-hr1 c -12 0v A-TB72-dd-hr1 c -2 00v A-TB72-dd-hr1c-220 v A-TB72-dd-hr1 c -24 0v A-TB72- q d-hr1c-ac f pr oduct t y pe s
 zzzehoohohfwulfdofrpdx 3 lvwkhjoredoqdphri0dwvxvklwd(ohfwulf:runv ac motor t y p e 100v ac , 110v ac , 120v a c 200v ac , 220v ac , 240v a c 1 00 to 24 0 v a c 50/60hz ( switchable ) 1. 5 w or les s in p ut/out p ut se p arate circui t manual switch p rovide d 1 5 a 2 50 v a c built-in settin g element swin g typ e 1 5 -minute intervals 1 5 minute s max. 48 ( on/off ) 200 hours or more ( at 2 5 ? c ) monthl y error: within 15 seconds ( at 2 5 ? c ) s y nchronous with power suppl y frequenc y c solder/tab common terminal: flush mountin g type, crimp terminal or bare wires: surface mountin g typ e 5 , 000 , 000 times or mor e 20,000 times or more ( on/off ) 80 to 110% of rated volta ge 85 to 115% of rated volta ge more than 1 00m ? t y pe s drive s y ste m volta ge frequenc y power consum p tio n c ircui t manual o n / a u t o capacit y ( resistive load ) settin g s y stem minim u m u ni t ninimum ran ge no. of settin g power failure com p ensatio n clock accurac y contact arran g emen t contact t y p e mechanical life ( contact ) electrical life ( at rated load ) allowable operatin g volta g e ran ge insulation resistance ( initial ) dielectric stren g th (initial ) sur g e resistanc e n o i se r es i s t a n ce tem p erature ris e m a lf u n c ti o n a l vi b r a ti on d es tr uc tiv e vi b r a ti on m a lf u n c ti o n a l s h ock d es tr uc tiv es h ock ambient operatin g temperatur e ambient operatin g humidit y wei g ht ( ) denotes surface mountin g typ e am b i e n t co n d iti o n s m ec h a ni cal c h a r ac t e ri s ti cs el ec tri cal c h a r ac t e ri s ti cs lif e time accurac y c ontac t s p ecification s l oad ratin g s p ecifications t erminal la t t y outs and wirin g dia g ram s dim e n s i o n s note ) protective cover is p rovided on A-TB72. mm in ch ? flush mountin g typ e ? flush mountin g typ e ( 1 form a ) ? surface mountin g typ e ( 1 form c ) ? p a n e l cu to u t d im e n s ion s ? surface mountin g typ e m a n ual s wit ch pr ese n t tim e di a l with bu ilt-i n settin g element s quartz p ower-failure com p ensation : power supply indicator ac motor type: hz selection time setting setting element o n- o f f position ??? ??? 72 2.835 67 2. 638 5.5 .217 27.2 1.071 32 1.260 39.2 1.543 75.2 2.961 (???) on state off state 65 0.2 2.559 .008 3-m4 screw hole 3-m.157 (or 4.2 0.1 hole) (or .165 .004 hole) 90 3.543 37.5 1.476 44 1.732 (42.5) (1.673) 90 0.2 3.543 .008 7 5 . 2 2 . 961 2 961 () ( ??? ) 72 2.835 rated operatin g volta ge lo ad 1 l 2 l 2 s 1 s rated operatin g volta ge lo ad com n c n o 2 s 1 s panel thickness: 1. 0 to 4. 5 mm . 039 to .177inc h (note) minimum pitch for close mountin g (note) 82 8 2 3 .22 8 m o r e o r ( note ) 82 3 .22 8 or mor e
zzzehoohohfwulfdofrpdx  3 lvwkhjoredoqdphri0dwvxvklwd(ohfwulf:runv precautions durin g usa ge 1. output settin g ? on settin g : turn the settin g elemen t inward, and red mark a pp ear around th e d i a l . ? off settin g : turn the settin g elemen t outward , and the above red mark will dis - a pp ear . ? turn the settin g element sufficientl y u ntil th ec li c k ac tion i s f e lt . 2. clock settin g ? b esu r e to t u rn th e kno ba t th ec lo ck ce nt e r in th ea rrow d ir ec tion to se t th e clock to the p resent time. ( the dial als o turns to g ether with the clock.) be sure t o prevent reverse turnin g. ? d o not t u rn th ed i a l to se t th ec lo c k . 3 . attachmen t ? in se rt th e tim es wit c h from th e front o f the attachment p anel . (one-touch s y stem: panel attachmen t model ) ? either use 3 . 8 or m4 wood screws fo r attachment , or use din rails with a widt h of 35 mm ( ata48011 ) . ( direct-attach - ment model ) 4. contact rela y operation if the powe r f a il s ? contact rela y s remain closed while th e p ower is off . 5. power failure compensation ( atb7 5 series ) ? an internal nickel cadmium batter y i s p rovided to com p ensate for p ower fail - ures, but the power suppl y should be lef t on as much as possible. turnin g th e power suppl y on and off shortens th e service life of the batter y. ? after continuous char g in g for 48 hours , the batter y provides 200 hours of powe r failure com p ensation. the internal bat - tery is fully char g ed, but if the batter y ca p acitance has dro pp ed because o f natural dischar g in g , or if the battery ha s dischar g ed completely, there may b e times when the switch does not o p erat e immediatel y when the power is turne d on. if this happens, set the clock to th e p ro p er time after the p ower has bee n bac k on for thr ee to fo u r ho u r s. ? ni c k e l cad mi u m ba tt e ri es a r ea v a l u- able commodity which can be rechar g ed . they cannot be replaced, but if bein g discarded after use, p lease make sur e the y are rec y cled if possible . when discardin g the battery, turn off th e power suppl y to the time switches, an d use radio pliers to disassemble the over - all connections and remove the batter y. 6. precautions concernin g wirin g with panel attachment models, wirin g should be connected by solderin g i t directly, or usin g the #187 flat connectin g probe provided as an accessor y. 7. ce markin g suppor t 1 ) emc directives ( 89/336/eec ) th e A-TB72 fl a t tim es wit c h c onform s t o em c directives as a stand-alone tim e s wit c h . a pp licable standards: en50081-2 , en 5008 2- 2 2) low-volta g e directives (73/23/eec ) in order to satisf y vde0435 part 2021 , the installation conditions and p recau - tion s not ed be low m us t be o bse rv ed. 1. wirin g connection s the power suppl y applied to the tim e switches should be protected b y an over - current p rotection device that conform s to en / ie c standards . 2. att ac hm e nt a n d r e mov al ( 1 ) with p anel attachment models, th e time switches are desi g ned for attach - ment to a p anel. the ends of the tim e s wit c h es s ho u l dbe fitt ed in s i de th e p anel . ( 2 ) with direct-attachment models, th e time switches are desi g ned to b e installed inside the p anel. do not touc h an y component of the time switch, suc h as the end section, while power is bein g su pp lied . (3) when attachin g or removin g th e switches , check first to make sure n o volta g e is bein g applied to any of the en d sec tion s. 3 . do not use these time switches i n safety circuits. for example, if usin g th e tim es wit c h es in h ea t c ir cu it s or s imil ar circuits, a p rotective circuit should b e p rovided on the mechanical side . 8. for other information, p lease refer t o "precautions concernin g a-tb tim e switches ( common ) " . o f f time switch settin g time p o w e r o f f


▲Up To Search▲   

 
Price & Availability of A-TB72

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X